Mostrar el registro sencillo del ítem
Calidad bacteriológica del aire en ambientes académicos administrativos de la Universidad Central del Ecuador.
| dc.rights.license | http://creativecommons.org/licenses/by-nc-sa/3.0/ve/ | es_VE |
| dc.contributor.author | González-Escudero, Marco | |
| dc.contributor.author | Chavez-Chamorro, Andrea | |
| dc.contributor.author | Araque-Rangel, Judith | |
| dc.contributor.author | Andueza-Leal, Félix | |
| dc.date.accessioned | 2024-01-15T16:32:27Z | |
| dc.date.available | 2024-01-15T16:32:27Z | |
| dc.date.issued | 2024 | |
| dc.identifier.issn | 0543- 517-X | |
| dc.identifier.uri | http://www.saber.ula.ve/handle/123456789/50138 | |
| dc.description.abstract | La contaminación del aire de los ambientes de trabajo es un problema resaltante a nivel mundial, constituyéndose en un fenómeno con incidencia en la salud del trabajador a través de infecciones y enfermedades crónicas, lo cual produce una reducción de la esperanza de vida de las personas, así como pérdidas económicas por el ausentismo laboral que provoca. En este sentido el objetivo de la presente investigación fue cuantificar la microbiota bacteriana del aire interior de unidades académico administrativas de la Universidad Central del Ecuador. El diseño experimental aplicado fue el de una investigación exploratoria, observacional descriptiva. Se recolectaron 304 muestras en 38 sitios seleccionados. Se utilizó como técnica de muestreo la deposición por gravedad utilizando placas Compact Dry ® para bacterias aerobias, expuestas por diez minutos en cada uno de los ambientes seleccionados, incubándose posteriormente a 37°C durante un máximo de 7 días. La cuantificación de bacterias aerobias se expresó en unidades formadoras de colonias por metro cubico. Los valores promedios más altos de colonias bacterianas se obtuvieron en los ambientes de las facultades de ciencias administrativas (8,40 x 10 2 ), filosofía (8,30 x 10 2 ), comunicación social (7,40 x 10 2 ) y del hospital del día universitario (7,52 x 10 2 ). Los resultados evidencian la presencia de una microbiota bacteriana en el aire interior de la mayoría de las instalaciones de la Universidad Central del Ecuador dentro de los límites establecidos a nivel internacional, lo cual representa un riesgo bajo para la salud de los usuarios. | es_VE |
| dc.language.iso | es | es_VE |
| dc.publisher | SaberULA | es_VE |
| dc.rights | info:eu-repo/semantics/openAccess | es_VE |
| dc.subject | Calidad bacteriológica | es_VE |
| dc.subject | Contaminación del aire | es_VE |
| dc.subject | Ambientes laborales universitarios | es_VE |
| dc.subject | Microbiota del aire | es_VE |
| dc.title | Calidad bacteriológica del aire en ambientes académicos administrativos de la Universidad Central del Ecuador. | es_VE |
| dc.title.alternative | Bacteriological air quality in academic administrative environments of the Central University of Ecuador. | es_VE |
| dc.type | info:eu-repo/semantics/article | es_VE |
| dc.description.abstract1 | Air pollution in workplaces is a significant problem worldwide and constitutes a phenomenon that has an impact on worker health, causing infections and chronic diseases, which affects a reduction in people's life expectancy as well as economic losses due to the work absenteeism, thus the objective of research was to quantify the bacterial microbiota of the indoor air of academic- administrative units of the Central University of Ecuador. The experimental design applied was that of an exploratory, descriptive observational research. 304 samples were collected at 38 selected points. Gravity deposition was used as a sampling technique using Compact Dry® plates for aerobic bacteria, exposed for ten minutes in each of the selected environments, subsequently incubated at 37 °C for a maximum of 7 days. The quantification of aerobic bacteria was expressed in colony- forming units per cubic meter. The highest average values of bacterial colonies of air were obtained in the environments of the faculties of administrative sciences (8.40 x 10 2 ), philosophy (8.30 x 10 2 ), and social communication (7.40 x 10 2 ) and the university day hospital (7.52 x 10 2 ). The results show the presence of a bacterial microbiota in the indoor air of most of the facilities of the Central University of Ecuador within the limits established internationally, which does not represent a risk to the health of users. | es_VE |
| dc.description.colacion | 82-92 | es_VE |
| dc.description.email | felixandueza@hotmail.com | es_VE |
| dc.description.frecuencia | Semestral | |
| dc.description.paginaweb | http://www.saber.ula.ve/farmacia/ | |
| dc.identifier.depositolegal | pp195802ME1003 | |
| dc.identifier.edepositolegal | ppi201202ME4102 | |
| dc.identifier.eissn | 2244-8845 | |
| dc.publisher.pais | Venezuela | es_VE |
| dc.subject.institucion | Universidad de Los Andes (ULA) | es_VE |
| dc.subject.keywords | Bacteriological quality | es_VE |
| dc.subject.keywords | Air pollution | es_VE |
| dc.subject.keywords | University work environments | es_VE |
| dc.subject.keywords | Air microbiota | es_VE |
| dc.subject.seccion | Revista de la Facultad de Farmacia: Articulos Originales | es_VE |
| dc.subject.tipo | Revistas | es_VE |
| dc.type.media | Texto | es_VE |
| dc.identifier.doi | https://doi.org/10.53766/REFA/2024.65.2.05 |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Revista de la Facultad de Farmacia - Volumen 65 (2)
Julio-Diciembre 2023


