Mostrar el registro sencillo del ítem

dc.rights.licensehttp://creativecommons.org/licenses/by-nc-sa/3.0/ve/
dc.contributor.authorSrilalitha, V.
dc.contributor.authorGuru Prasad, A. Raghavendra
dc.contributor.authorKumar, K. Raman
dc.contributor.authorSeshagiri, V.
dc.contributor.authorRavindranath, L. K.
dc.date.accessioned2011-01-25T20:06:38Z
dc.date.available2011-01-25T20:06:38Z
dc.date.issued2011-01-25T20:06:38Z
dc.identifier.isbn1856-3201es_VE
dc.identifier.urihttp://www.saber.ula.ve/handle/123456789/32215
dc.description.abstractUn método espectrométrico rápido, simple y sensible ha sido desarrollado para la determinación de Fe(III) y Ni(II) usando la hidrazona del ácido saliciladehido acetoacético (SAAH) como reactivo cromofórico. Las curvas de calibración lineal fueron obtenidas en cada caso. El método propuesto es aplicado para la determinación simultánea de Fe(III) y Ni(II) empleando su espectros de primer orden. El método está basado en la medición de cruzamiento cero de las amplitudes de la primera derivada. Las amplitudes de la primera derivada a 525 nm y 395 nm obedecen la ley de Beer en el rango de concentración 0,054-0,270 μg/mL y 0,112-0,561 μg/mL para Fe(III) y Ni(II), respectivamente. Un gran número de iones no interfieren en el presente método. El método es usado para la determinación de cantidades micro de Fe(III) y Ni(II) en mezclas de acero y en mezclas sintéticas.es_VE
dc.language.isoeses_VE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEspectrofotometríaes_VE
dc.subjectFe(III)es_VE
dc.subjectNi(II)es_VE
dc.subjectDeterminación simultáneaes_VE
dc.subjectMedición a cruzamiento ceroes_VE
dc.subjectApplicacioneses_VE
dc.titleDirect and simultaneous spectrophotometric determination of Fe (III) and Ni (II) using salicylaldehyde acetoacetic acid hydrazone – applicationses_VE
dc.typeinfo:eu-repo/semantics/article
dc.description.abstract1A rapid, simple and sensitive spectrophotometric method has been developed for determination of Fe (III) and Ni (II) using salicylaldehyde acetoacetic acid hydrazone (SAAH) as a chromophoric reagent. The linear calibration ranges were obtained in each case. The proposed method is applied for the simultaneous determination of Fe (III) and Ni (II) utilizing their first order spectra. The method is based on the zero crossing measurement of first derivative amplitudes. The first derivative amplitudes at 525 nm and 395 nm obey Beer's law in the concentration range 0.054-0.270 μg/mL and 0.112-0.561 μg/mL for Fe (III) and Ni (II) respectively. A large number of foreign ions do not interfere in the present method. The method is used for the determination of micro amounts of Fe (III) and Ni (II) in alloy steels and in synthetic mixtures.es_VE
dc.description.colacion153-159es_VE
dc.description.emailguruprasadar@yahoo.co.ines_VE
dc.description.frecuenciacuatrimestrees_VE
dc.identifier.depositolegal200502ME2052es_VE
dc.subject.departamentoDepartamento de Químicaes_VE
dc.subject.facultadFacultad de Cienciases_VE
dc.subject.keywordsSpectrophotometryes_VE
dc.subject.keywordsSimultaneous determinationes_VE
dc.subject.keywordsZero crossing measurementes_VE
dc.subject.keywordsApplicationses_VE
dc.subject.publicacionelectronicaRevista Avances en Químicaes_VE
dc.subject.seccionRevista Avances en Química: Artículos Científicoses_VE
dc.subject.thematiccategoryQuímicaes_VE
dc.subject.tipoRevistases_VE
dc.type.mediaTextoes_VE


Ficheros en el ítem

Thumbnail
Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem